MONARCH INSTRUMENT
15 Columbia Drive
Amherst, NH 03031-2334 USA
Phone: (603) 883-3390
Fax: (603) 886-3300
Website: www.monarchinstrument.com
Instruction Manual
Vibration Strobe
Printed in the U.S.A. © Monarch Instrument 2002 all rights reserved
1071-4800-121
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - Vibration Strobe

MONARCH INSTRUMENT15 Columbia DriveAmherst, NH 03031-2334 USAPhone: (603) 883-3390Fax: (603) 886-3300E-mail: [email protected]:

Strona 2 - Safeguards and Precautions

Safeguards and Precautions1. Read and follow all instructions in this manual carefully, and retainthis manual for future reference.2. Do not use this

Strona 3 - TABLE OF CONTENTS

SPECIFICATIONSFlash Rate Range: 100-12,000 FPM (Flashes Per Minute)Locking Range: Wide Mode: 600 to 10,000 RPMNarrow Mode: 200 to 8,000 RPMAccuracy: ±

Strona 4 - REPAIR/SERVICE/PARTS

Figure 1 Display Panel1INTRODUCTIONThe Vibration Strobe is a truly portable, battery-operated stroboscope that is suited for a wide rangeof industria

Strona 5 - PREPARATION FOR USE

2PREPARATION FOR USEThe Vibration Strobe is a portable lightweight strobe flash unit with internal battery that will flash formore than 1 hour at 1800

Strona 6 - LAMP REPLACEMENT

3OPERATIONTo turn on the stroboscope, depress and hold the trigger. When the strobe is powered up in theInternal (INT) mode, it will begin flashing i

Strona 7 - MOTION STUDIES

4The Narrow and Wide Bandwidth selector on the strobe’s front panel can be used to optimize its’ability to lock onto the vibration signal at any speed

Strona 8 - PHASE ANALYSIS

5To set-up for balancing or phase measurement, a data collector or vibration analyzer must be usedthat is capable of interfacing with the Vibration St